- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources4
- Resource Type
-
0001000003000000
- More
- Availability
-
22
- Author / Contributor
- Filter by Author / Creator
-
-
Costanzo, Ian (2)
-
Guler, Ulkuhan (2)
-
McNeill, John (2)
-
Sen, Devdip (2)
-
Amundson, Ronald (1)
-
Ashley, Gail M (1)
-
Bacon, Allan R (1)
-
Bales, Roger C (1)
-
Billings, Sharon A (1)
-
Binkley, Dan (1)
-
Brantley, Susan L (1)
-
Brecheisen, Zachary (1)
-
Calvo‐Alvarado, Julio (1)
-
Cassar, Nicolas (1)
-
Clifford, Chelsea (1)
-
Derry, Louis A (1)
-
Edgeworth, Matt (1)
-
Eppes, Martha‐Cary (1)
-
Fan, Ying (1)
-
Ferguson, Terry A (1)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Free, publicly-accessible full text available August 1, 2026
-
Costanzo, Ian; Sen, Devdip; McNeill, John; Guler, Ulkuhan (, IEEE 48th European Solid State Circuits Conference (ESSCIRC))This paper presents a nonuniform sampling technique for measuring the lifetime of luminescent materials for oxygen sensing. The system features a switched-capacitor circuit to implement fixed-voltage steps for quantization, enabling long integration times without saturating the front-end amplifier. A control circuit automatically tunes the light emitting diode (LED) excitation pulses to avoid overpowering or starving the front end as photodiode current varies with changes in the partial pressure of oxygen. Time gating of the front-end integrator removes the need for optical filtering. The analog front end (AFE) has a gain bandwidth product of 10 MHz and an input-referred noise of 124 μVrms (measured 200 Hz - 100 kHz). The circuit was realized in 180 nm CMOS technology. The AFE and LED driver consume a maximum of 16 μJ per calculation. We have demonstrated the entire system's functionality by measuring oxygen concentrations from 0 to 240 mmHg in a controlled gas vessel. The results indicate satisfactory linearity on a Stern-Volmer plot covering the human-relevant range of 50 to 150 mmHg.more » « less
-
Richter, Daniel D; Billings, Sharon A; Brantley, Susan L; Gaillardet, Jerome; Markewitz, Daniel; Schlesinger, William H; Amundson, Ronald; Ashley, Gail M; Bacon, Allan R; Bales, Roger C; et al (, Perspectives of Earth and Space Scientists)After 4.5 billion years as an evolving and dynamic planet, the Earth continues to evolve but with human‐altered dynamics. Earth scientists have special opportunities and responsibilities to accelerate our understanding of Earth's changes that are transforming our most remarkable home.more » « lessFree, publicly-accessible full text available December 1, 2025
-
Murkli, Steven; McNeill, John N.; Isaacs, Lyle (, Supramolecular Chemistry)
An official website of the United States government
